1. Characteristics
l Introducing exclusive proprietary technology from , Germany ZOLLNER Company;
l Low inertia, high accuracy and stability, simple structure, convenient maintenance;
l Equipped with protective devices such as water pressure meter, water inflow switch, eddy current ring temperature sensor, oil sensor, etc.
2. Technical Parameters
l Measuring accuracy of torque excels ±0.2% FSR;
l Sensitivity of measuring torque excels ±0.1% FSR;
l Error limit of measuring speed is less than ±1r/min;
1.2 Disc Type Model Table:
Model |
Rated power (KW) |
Max. torque (N·m) |
Max. speed (r/min) |
Rotate inertia(Kg·m2) |
Max. water consump. (m3/h) |
Current (full load) (A) |
Weight
(Kg) |
CW550-1500/5000 |
550 |
3500 |
5000 |
2.758 |
23.65 |
21.3 |
3500 |
CW850-1500/3000 |
850 |
1500 |
3000 |
4.437 |
36.55 |
13.7 |
4200 |
CW1350-1500/3000 |
1300 |
1500 |
3000 |
8.647 |
55.9 |
17 |
5800 |
We will give you feedback in time